Tuning audits for LuxPower hybrid solar systems
Your solar system should last the night. Let's find out why it doesn't.
We read every setting, fault and five-minute history record on your inverters, check them against your battery's datasheet, and tell you in plain language what's wrong and what to change. Nothing changes without your approval.
- Read-only by default
- Remote across South Africa
- From R2,500 per system
Sound familiar?
Hybrid systems are usually installed correctly, then drift. A battery is added, a second inverter goes in, a setting is changed over the phone. Months later these are the symptoms.
The batteries don't last the night
The grid takes over at 23:00 when it used to be 02:00, or the backup fails during load-shedding.
"Battery open" and other warnings
The app shows warnings you don't understand, sometimes dozens a night.
The bill stayed high
You went solar, but the electricity bill barely moved, or went up.
More panels, no more power
Panels were added, but the system produces about the same as before.
For home and business owners
A second opinion on your system, from your own data
You don't need to understand inverters. We do the reading and give you a report you can follow, with the reasons behind every recommendation and what each change should do.
- Why the batteries cut out, and how often it happens
- Whether the charge and cut-off voltages suit your exact battery model
- Whether two or more inverters are set up to match
- Whether your panels are being used or throttled back
- Where the electricity bill really comes from, including circuits that aren't on the inverters
- Settings that were changed since the last check
We work with your installer, not around them. The report is written so your installer can check it and make the changes, or we can make them with your written approval.
Book an auditFor solar installers and electricians
Fewer call-backs. Answers without a long site visit.
"The batteries don't last any more" can take hours in the portal and a spreadsheet. Our tool reads the whole system, decodes every fault and warning, and checks every setting on every inverter in a parallel group against the battery datasheet. You get the cause and the evidence to show your customer.
- Every fault (E0xx) and warning (W0xx) code decoded with a recommended action; dangerous faults are flagged for an electrician, never "optimised around"
- Parallel groups checked for mismatched settings
- Weeks of five-minute history analysed night by night, with matching weather
- Hidden changes found, such as a charge voltage altered months ago
- Reports under your company name with white-label branding
- Your limits respected: it never raises a charge voltage above the limit you set
How an audit works
Connect, read-only
Through the LuxPower portal while you or your installer are signed in, or through the inverter's Wi-Fi dongle on your own network. Nothing is changed.
Read everything
Live readings, every user setting, the full fault and warning history, and the portal's five-minute history exports for the last weeks.
Analyse
Settings are checked against your battery's datasheet and your goal (backup first, balanced or savings). Every night is analysed with that night's weather.
Report
A plain-language diagnosis and a numbered change plan. You decide what to approve.
Change, only if you approve
Each approved setting is backed up, written one at a time and read back. One step restores the backup if anything looks wrong.
Case study, anonymised
A two-inverter home in Gauteng
Two 5 kW inverters in parallel, four 5 kWh lithium batteries and extra panels added a few months after the first install. The owner's complaint: the grid took over at about 23:00 instead of 02:00, and the bill was about R14,000 a month. This is what the read-only audit found.
- 40 VCut-off setting, against the battery's rated minimum of 48 V. The batteries were drained below their limit every night.
- 27"Battery open" drop-outs a night, as the batteries' own protection cut in and out.
- 11.7 kWhDelivered a night, down from 14 to 15 kWh a few months earlier.
- R1,450A month of grid power through the inverters. Most of the R14,000 bill came from circuits not on the inverters at all.
The key fix cost nothing: hand over to the grid before the batteries reach their rated minimum. The report also showed that the extra panels were being throttled back for lack of anything to power, and that the pool pump, which ran only on grid power, could run on that unused midday solar instead.
Safe by design
Reading is the default
Nothing on the inverter changes until you approve a specific list of changes.
A strict allowlist
Grid-code, protection, model and communication settings are never touched. Every value is checked against a safe range first.
Drift check
If any setting changed between the report and your approval, the change is refused until the system is read again.
Backup, read-back, rollback
Every write is backed up first and read back after. One step restores the backup.
No passwords in files
We prefer to read while you're signed in, so we never see your password. If a login is used, it lives in the computer's keychain, never in a file or report.
Your data stays private
Serial numbers and readings stay in private storage and are never published. Case studies are anonymised.
Pricing
South African rand, excluding VAT. Artificial Intelligence costs are included in every price. Prices are reviewed every six months.
System audits for owners and installers
Single inverter
Full read, settings and fault check, report and change plan.
R2,500 per system
Parallel or multi-inverter
As above, plus the night-by-night analysis of weeks of history with matching weather.
R3,500 per system
Re-check after changes
Before-and-after comparison on matching weather, to show the fix worked.
R950 per system
Installer tools for installers and electricians
Installer licence
Your own team runs the tool on your systems, with onboarding and support. Per user.
R3,950 a monthor R39,500 a year, two months free
White-label reports
Owner reports carry your branding only.
R500 a monthor R300 a report
Pilot offer
The first five installers get 50% off for their first six months, in return for feedback and a short testimonial.
50% off
Questions
Which inverters do you cover?
LuxPower hybrid inverters in the SNA and LXP ranges, single or in parallel, and EG4 units built on the same platform. Any battery works: lithium batteries that communicate with the inverter, and voltage-only batteries in lead-acid mode.
Will you change my settings?
Not unless you approve specific changes in writing. The audit itself is read-only. Many owners prefer their installer to make the approved changes; the report is written so they can.
Do you need my portal password?
Usually not. We can read the portal while you or your installer are signed in, or read the inverter's Wi-Fi dongle on your home network. If a login is ever used, it is kept in the computer's keychain and never written to a file or report.
Do you need to visit?
No. Most audits are done remotely through the portal. A site visit, or a photo from you, is only needed for physical checks such as battery labels, cabling or breakers, and the report says exactly what to look at.
Will this replace my installer?
No. We give you and your installer the evidence. Where the fix is physical, such as wiring or a failing battery, the report points your installer or electrician to it.
Is this a LuxPower service?
No. Solar System Auditors is an independent service by Terminal Velocity AI. It is not made, endorsed or supported by LuxPower, EG4 or any battery manufacturer.
What makes a parallel system cost more?
Two or more inverters must be checked against each other as well as the battery, and we analyse weeks of five-minute history night by night with the matching weather, which is where problems in parallel systems show up.
Book an audit or talk to us
Tell us a little about the system and we'll reply by email. Your details go straight into an email from your own email app. Nothing is stored on this website.
Email: terminalvelocityai@gmail.com
WhatsApp: Message us
What happens next
- We reply by email to agree a time and the way we'll read the system: the portal while you're signed in, or the Wi-Fi dongle.
- We read the system, read-only. If you have them, send the battery model or a photo of its label, and your installer's limits.
- You get the report and change plan, and decide what, if anything, to approve.